Safewire HTD-626AS-C TUV CE certificated access floor boxes cavity floor boxes EV charging station

Short Description:

 


  • Port: Wenjiang
  • Technical Parameters

    Application:

    Product Show:

    Product Tags

    Quick Details:

    Serial No. Parameter Description

    1

    Safewire item

    HTD-626AS-45

    2

    Material

    ABS, galvanised steel

    3

    Overall Frame & Lid (mm)

    320.5*230.5

    4

    Compact floor cut-out(mm)

    (305-310)*(210-215)*(76-110)

    5

    Thickness of concavity/Frame lid recess (mm)

    8

    6

    Installation depth(mm)

    76~110

    7

    Plug top clearance(mm)

    14~48

    8

    Available modules

    8 ways modules

    9

    Accessories plates

    90*80mm

    Application:

    1.Feature of Safewire floorbox:

    1.More capacity:8,12,16,24 way 45*45mm modules ; or 3 compartments bridges:

    2.More optional switch & socket: International 45*45mm modules,86 type,120 type etc.

    3.More optional installation:Horizontal,Side-mounting, Side-mounting & Horizontal;

    4.More Optional surface with carpet/Marble .

    5.More optional box for raised floor or concrete floor: Galvanized box, Stainless steel box and plastic box etc.

    2.Advantage of Safewire floorbox : 

    3.Specification of Safewire floorbox :

    A)Product dimension:

    B)Available installation modules/socket/accessories:

    C)FACTA class/EN124 class load of coverplate:

    D)Safewire floorbox Application in different floor system:

    E)Safewire optional of economical package :

    1.Floor box(For concrete floor)

    Align floor box in centre as delivered.Bend open ears and fix to raw ceiling.

    2.Steel armored conduit(For trunking system/Access floor).Bend open perforation in the sides of floor box and insert steel armored conduct.

    3.Put under floor box into cut out and adjust height(For raised floor) .Put under floor box into hole/location of raised floor.Then move the adjustable screw in clockwise direction until screws are tightened with flooring.lead the lines into plastic bottom box.

    4.Installing Heavy current/Data systems

    Insert heavy current devices from the top and connect from below and snaptabs into the frame;Insert connected data Jacks from below into the plate,Fasten equipped plate accordingly.

    5.Connecting and earthing.

    Connect heavy carrent/Data with the lines which are lead into bottom box.And connect earthing lines of floor cable systems with earthing screw of bottom box torgue0.4N.m.Verify reliable and safe.

    6.Assembly and plug into underfloor box.

    Inset heavy carrent and low carrent plugs into frame.

    7.Single outlet

    Lead heavy and low carrent plug cable cord from edge lord outlet lid.

    Filling stuff and levelling to floor

    Fill the sunken area of panel neatly with filling stuff according surface material of floor .Adjust wnder floor box height flush over the four levelling screws.

     

    Attentions:

    1.Dispose of trash in bottom box and prevent dirt and debris from entering inside.

    2.The sealing ring is closely attached to the smooth surface to prevent water leakage.

    3.When installing, pay attention to the opening direction,the length of the conductor to the bottom box shall not exceed 10cm,Set aside at least 200mm of cable.

    4.When installing and wiring,Product should avoid direct contact with corrosive liquid, gas (strong acid, strong alkali, paint).

    5.Please close cover when not used.

     

    Safety Warning

    1.This is a class I product and must be earthed

    2.This product must be installed/wired by a qualified electrician

    3.For indoor use only.

    4.For concrete floor/access floor.base on different bottom box.

     

     

     